{"id":6437,"date":"2025-11-29T11:48:34","date_gmt":"2025-11-29T10:48:34","guid":{"rendered":"https:\/\/www2igg.cnr.it\/?page_id=6437"},"modified":"2026-03-26T15:44:19","modified_gmt":"2026-03-26T14:44:19","slug":"laboratorio-misure-flusso-di-calore","status":"publish","type":"page","link":"https:\/\/www.igg.cnr.it\/en\/laboratorio-misure-flusso-di-calore\/","title":{"rendered":"Heat Flow Measurement Laborator"},"content":{"rendered":"<h6 class=\"wp-block-heading\">The assessment of the surface heat flux (HF) distribution is a fundamental element in geothermal prospecting methods, allowing the identification of thermally anomalous areas at relatively modest costs and providing an immediate indication of the geothermal potential of an area.<\/h6>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion  root-eb-accordion-63d5q\"><div class=\"eb-parent-wrapper eb-parent-eb-accordion-63d5q\"><div class=\"eb-accordion-container eb-accordion-63d5q\" data-accordion-type=\"accordion\" data-tab-icon=\"dashicons-plus-alt2\" data-expanded-icon=\"dashicons-minus\" data-transition-duration=\"500\"><div class=\"eb-accordion-inner\">\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-jbbes eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">The Laboratory<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<p class=\"wp-block-paragraph\">Thermal geothermal exploration methods (well temperature measurements and calculation of geothermal gradients; thermal conductivity measurements on rock samples) are, moreover, the only ones that allow a direct measurement of the quantity \u201cheat\u201d which is the ultimate goal of exploration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The product of the geothermal gradient value of an area (\u2206t\/\u2206z) by that of the thermal conductivity of the rocks (k) gives the value of the heat flux (Q), according to the relation:<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><br>Q = k x \u2206t\/\u2206z (Q = mWxm<sup>-2<\/sup>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>The main product of the laboratory's activity is the heat flow and\/or geothermal gradient maps of the investigated area.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These maps represent the basis of geothermal exploration. However, depending on data availability and the study's objectives, different combinations of direct comparisons of HF with other geophysical, geochemical, and structural parameters are possible, allowing for a comprehensive view of an area's geothermal characteristics. They provide fundamental information on the physical and chemical nature of fluids present in the past in various geological environments. The primary analytical method is microthermometric analysis, based on the temperatures at which phase transitions occur within fluid inclusions. Fluid inclusion analyses are commonly used in the study and prospecting of mineral deposits, geothermal exploration, and petroleum exploration; in metamorphic, magmatic, and sedimentary petrology; and in research on the relationships between fluid circulation and tectonic structures, etc.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"945\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig1.jpeg\" alt=\"\" class=\"wp-image-6447\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig1.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig1-254x300.jpeg 254w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig1-768x907.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Heat flow map of the area west of Monte Amiata. The gradient wells measured during geothermal exploration are indicated.<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"667\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig2.jpeg\" alt=\"\" class=\"wp-image-6446\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig2.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig2-300x250.jpeg 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig2-768x640.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Geothermal gradient map of Tuscany in the area including the Larderello and Monte Amiata geothermal fields.<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"427\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig3.jpeg\" alt=\"\" class=\"wp-image-6445\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig3.jpeg 650w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig3-300x197.jpeg 300w\" sizes=\"auto, (max-width: 650px) 100vw, 650px\" \/><figcaption class=\"wp-element-caption\">Comparison of HF, Bouguer gravimetric anomaly, He isotope ratio and seismic reflector depth \u201cK\u201d in the Tuscan geothermal fields of Larderello and Monte Amiata<\/figcaption><\/figure>\n<\/div><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-xfxnw eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">Instruments<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<p class=\"wp-block-paragraph\">Currently, a manually operated instrument with a 450 m long, four-conductor, Teflon-coated cable is available for in-well temperature measurements; the acquisition sensor consists of a 100 Ohm nominal Pt100 platinum resistance thermometer, with a sensitivity of +\/- 0.01 \u00b0C and an accuracy of +\/- 0.03 \u00b0C. The \u201cCorradi RP 2000 S\u201d temperature control and indicator instrument is also available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal conductivity is measured in the laboratory on core samples taken from wells or rock outcrops. The samples are prepared in the IGG Rock Grinding and Mineral Separation Laboratory.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>There are two linear source instruments available:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Shotherm QTM Showa Denko;<\/li>\n\n\n\n<li>Self-built instrument in collaboration between IGG and IPCF CNR, with characteristics similar to the Shotherm QTM;<\/li>\n\n\n\n<li>An Isomet 2114 instrument is also available, alternatively equipped with a planar source or a Maxwell needle probe.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The following codes are used for thermal modelling of the studied areas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>USGS Hydrotherm 3.1 (2D);<br>Shemat 7.1 (2D\u20133D) (University of Aachen).<br>For contouring and thermal section and graphing:<\/li>\n\n\n\n<li>SURFER 13\u00a9 (Golden Software);<br>GRAPHER 11\u00a9 (Golden Software);<br>DIDGER 4\u00a9 (Golden Software).<\/li>\n<\/ul>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"449\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig7.jpeg\" alt=\"\" class=\"wp-image-6450\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig7.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig7-300x168.jpeg 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig7-768x431.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Showa Denko \u201cShotherm QTM\u201d instrument for measuring thermal conductivity with a linear source.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"451\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig8.jpeg\" alt=\"\" class=\"wp-image-6449\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig8.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig8-300x169.jpeg 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig8-768x433.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Self-built instrument with linear source similar to the Showa Denko Shotherm QTM.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"645\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig9.jpeg\" alt=\"\" class=\"wp-image-6448\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig9.jpeg 640w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig9-298x300.jpeg 298w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig9-150x150.jpeg 150w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><figcaption class=\"wp-element-caption\">Isomet 2114 instrument with planar source (or, alternatively, needle probe).<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"688\" height=\"569\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig10.jpeg\" alt=\"\" class=\"wp-image-6441\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig10.jpeg 688w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig10-300x248.jpeg 300w\" sizes=\"auto, (max-width: 688px) 100vw, 688px\" \/><figcaption class=\"wp-element-caption\">Instrumentation for measuring temperature in the well. Reel with 450 m of 4-wire cable, Pt100 acquisition sensor. \u201cCorradi RP 2000 S\u201d measuring instrument.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-7e36t eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">Staff and Contacts<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<p class=\"wp-block-paragraph\">The staff of the isotopic chemical laboratory is composed of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dr. Stefano Bellani (CNR Researcher \u2013 Head of Laboratory, Pisa headquarter)<\/li>\n\n\n\n<li>Dr. Gianluca Gola (CNR Researcher \u2013 Head of Laboratory, Turin UOS)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Contacts<\/strong>:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>+39 050 6213286 (Dr. Stefano Bellani)<\/li>\n\n\n\n<li>+39 3805038398 (Dr. Gianluca Gola)<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-559j7 eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">Methods and Applications<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<p class=\"wp-block-paragraph\">Microthermometric analyses are at the base of all fluid inclusion study. Microthermometry is carried out by using a heating\/cooling stage mounted on an optical microscope, trough which is possible to observe and record the temperature of phase changes that take place in the fluid inclusions during controlled thermal cycles. On the basis of the recorded temperatures it is possible to obtain information on some chemical-physical parameters of the trapped fluids, for example: the salinity and the molar volume of aqueous solutions, the presence of CO<sub>2<\/sub> (and sometimes CH<sub>4<\/sub> and\/or N<sub>2<\/sub>) in the fluids, the molar volume of fluid inclusions containing exclusively CO<sub>2<\/sub> or CH<sub>4<\/sub> or N<sub>2<\/sub>Furthermore, by integrating the microthermometric information with data obtained by RAMAN micro-spectroscopy, it is possible to reconstruct the temperature changes in the inclusions. In addition to calculating heat flow and geothermal gradients, precision well temperature measurements also have other applications in the earth sciences. This laboratory has conducted and continues to conduct activities in the identification and monitoring of groundwater aquifers, including in mining (underground rock salt mines), and in paleoclimate reconstructions using data from wells whose temperatures do not show evidence of groundwater circulation. Another field in which measuring terrestrial heat flow and geothermal gradients is of fundamental importance is that of medium- to low-enthalpy geothermal applications, a rapidly expanding sector for reasons of energy saving and environmental protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The results of the field (well measurements) and laboratory (thermal conductivity measurements) activities are integrated with other parameters and processed with 2D and 3D thermal modeling performed with the calculation codes Hydrotherm 3.1 (USGS) and Shemat 8.0 (University of Aachen). In collaboration with colleagues at IGG and foreign universities, thermal modeling was carried out with more complex codes (TOUGH2). This provides information on the composition and molar volume of aqueous solutions containing volatile phases (CO<sub>2<\/sub> and\/or CH<sub>4<\/sub> and\/or N<sub>2<\/sub>).<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"799\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig12.jpeg\" alt=\"\" class=\"wp-image-6444\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig12.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig12-300x300.jpeg 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig12-150x150.jpeg 150w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig12-768x767.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Precision thermal logs for monitoring water circulation in an underground rock salt deposit<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"217\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig13.png\" alt=\"\" class=\"wp-image-6443\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig13.png 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig13-300x81.png 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig13-768x208.png 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">2D thermal model across an area northwest of the Larderello geothermal field, performed with the SHEMAT 7.1 code<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"423\" src=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig14.jpeg\" alt=\"\" class=\"wp-image-6442\" style=\"width:600px\" srcset=\"https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig14.jpeg 800w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig14-300x159.jpeg 300w, https:\/\/www.igg.cnr.it\/wp-content\/uploads\/2025\/11\/lab-flusso-calore-Fig14-768x406.jpeg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Heat flow map of the Pisa plain (mWm-2), with indication of soundings with depths up to 300 m (S) and up to 3000 m (D)<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:3px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-vfbnk eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">Scientific Projects and Interests<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<p class=\"wp-block-paragraph\">Most of the laboratory's activities are conducted in collaboration with research institutions and industries. The latter also represent the main source of funding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Among others, but not limited to, collaborations have been and\/or are active with:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Industry:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ENEL<\/li>\n\n\n\n<li>Solvay Chemical Company<\/li>\n\n\n\n<li>Steam<\/li>\n\n\n\n<li>Sorgenia.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Research institutions:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>INGV<\/li>\n\n\n\n<li>Southern Methodist University (Dallas, USA)<\/li>\n\n\n\n<li>Universities of Trieste, Genoa, Rome, Bologna, Lugano (CH).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The laboratory is also currently involved in the \u201cHorizon 2020 \u2013 DESCRAMBLE (2015-2018)\u201d project for deep drilling in the Larderello geothermal field.<\/p>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-essential-blocks-accordion-item eb-accordion-item-m6ny3 eb-accordion-wrapper\" data-clickable=\"false\"><div class=\"eb-accordion-title-wrapper eb-accordion-title-wrapper-eb-accordion-63d5q\" tabindex=\"0\"><span class=\"eb-accordion-icon-wrapper eb-accordion-icon-wrapper-eb-accordion-63d5q\"><span class=\"dashicon dashicons dashicons-plus-alt2 eb-accordion-icon\"><\/span><\/span><div class=\"eb-accordion-title-content-wrap title-content-eb-accordion-63d5q\"><h3 class=\"eb-accordion-title\">Publications<\/h3><\/div><\/div><div class=\"eb-accordion-content-wrapper eb-accordion-content-wrapper-eb-accordion-63d5q\"><div class=\"eb-accordion-content\">\n<ul class=\"wp-block-list\">\n<li>Bellani S., Magro G., Gherardi F. (2015). \u201cHeat Flow and Helium Isotopes in the Geothermal Areas of Tuscany (Central Italy)\u201d. Geothermal Resources Council Transactions, vol. 39, p. 399-405.<\/li>\n\n\n\n<li>Bellani S., Gherardi F. (2014). \u201cThermal Features of the Pisa Plain, a Neogenic Basin in Central Italy\u201d. \u2013Geothermal Resources Council Transactions, vol. 38, p. 357-361.<\/li>\n\n\n\n<li>Bellani S., Gherardi F. (2013). \u201cThermal Overview of an Area NW of the Larderello Geothermal Field, Italy\u201d. \u2013 Geothermal Resources Council Transactions, vol. 37, p. 231-235.<\/li>\n\n\n\n<li>Magro G., Gherardi F., Bellani S. (2010): \u201cNoble gases in karstic and thermal waters of Strimon basin (Greece-Bulgaria)\u201d. Water-Rock Interaction Symposium, Guanajuato, Mexico, p. 345-348.<\/li>\n\n\n\n<li>Bellani S., Gherardi F. (2009). \u201cThermal Modeling of an Area West of the Mt. Amiata Geothermal Field, Italy\u201d. \u2013 Geothermal Resources Council Transactions, vol. 33, p. 431-435.<\/li>\n\n\n\n<li>Magro G., Bellani S., Della Vedova B. (2009). \u201cThe deep roots of the Larderello geothermal field (Italy) from heat flux and 3He anomalies\u201d. Geothermal Resources Council Transactions, vol. 33, p. 405-409.<\/li>\n\n\n\n<li>Della Vedova B., Vecellio C., Bellani S., Tinivella U.,(2008). \u201cThermal modelling of the Larderello geothermal field (Tuscany, Italy)\u201d. Int. Journal of Earth Sciences, 97, 317-332.<\/li>\n\n\n\n<li>Pasquale V., Verdoya M., Chiozzi P., Bodri L., Bellani S. (2005) \u201cTemperature signal in the underground for climate history reconstruction in Italy\u201d. Global and Planetary Change, 47. pp. 36-50<\/li>\n\n\n\n<li>Bellani S., G. Magro, A. Brogi, A. Lazzarotto and D. Liotta, (2005). \u201cInsights into the Larderello geothermal field: structural setting and distribution of thermal and 3He anomaly\u201d. Proceedings of World Geothermal Congress, Antalya, Turkey, 24-29 April 2005. pp. 1-4.<\/li>\n\n\n\n<li>Bellani S., Brogi A., Lazzarotto A., Liotta D., Ranalli G. (2004) \u201cHeat flow, deep temperatures and extensional structures in the Larderello geothermal field (Italy): constraints on geothermal fluid flow\u201d. Journal of Volcanology and Geothermal Research, 132, 15-29.<\/li>\n\n\n\n<li>Magro G., Gianelli G., Ruggieri G., Bellani S., Scandiffio G. (2003) \u2013 \u201cHelium isotopes in paleofluids and present-day fluids of the Larderello geothermal field: Constraints on the heat source\u201d. Journal of Geophysical Research, v. 108, n. B1, ECV3, 1-12.<\/li>\n\n\n\n<li>Della Vedova B., Bellani S., Pellis G., Squarci P. (2001) \u2013 \u201cChapter 7: Deep temperatures and surface heat flow distribution\u201d. In: Anatomy of an orogen, The Apennines and adjacent Mediterranean basins, (Editors : Vai G.B., Martini I.P.). Kluwer Acad. Publ., Dordrecht, The Netherlands, pp. 65-76 + 2 plates.<\/li>\n\n\n\n<li>Bellani S., Buonasorte G., Grassi S., Squarci P. (1998): \u201cGeological and structural features of the San Cataldo district heating project (Pisa, Italy)\u201d. \u2013 Proceedings 5th World Renewable Energy Congress, Florence, Vol. 4, pp. 2746-2749.<\/li>\n\n\n\n<li>Baldi P., Bellani S., Buonasorte G., Fiordelisi A., Manzella A. (1998): \u201cGeothermal exploration in Tuscany (Italy) for high temperature resources.\u201d &#8211; Proceedings 5th World Renewable Energy Congress, Florence, Vol. 4, pp., 2733-2736.<\/li>\n\n\n\n<li>Wisian K.W., Blackwell D.D., Bellani S., Henfling J.A., Normann R.A., Lysne P.C., Forster A., Schrotter J. (1998): &#8220;Field comparison of conventional and new technology temperature logging systems&#8221; \u2013 Geothermics, Vol. 27, n.2, pp. 131-141.<\/li>\n\n\n\n<li>Wisian K.W., Blackwell D.D., Bellani S., Henfling J.A., Normann R.A., Lysne P.C., Forster A., Schrotter J. (1996): &#8220;How hot is it ? (A comparison of advanced technology temperature logging systems)&#8221; \u2013 Geothermal Resources Council Transactions Vol. 20, pp. 427-434<\/li>\n\n\n\n<li>Baldi P., Bellani S., Ceccarelli A., Fiordelisi A., Squarci P., Taffi L. (1995) : &#8220;Geothermal anomalies and structural features of southern Tuscany&#8221; &#8211; &#8220;World Geothermal Congress Proceedings&#8221;- Florence, May 1995, pp. 1287-1291.<\/li>\n\n\n\n<li>Bellani S., Grassi S., Squarci P.(1995) : &#8220;Geothermal characteristics of the Pisa plain&#8221; &#8211; &#8220;World Geothermal Congress Proceedings&#8221; &#8211; Florence, May 1995, pp. 1305-1308.<\/li>\n\n\n\n<li>Bellani S., Calore C., Grassi S., Squarci P. (1995): &#8220;Thermal prospecting in Pantelleria island (Sicily Channel, Italy)&#8221; \u2013 \u201cWorld Geothermal Congress Proceedings&#8221; &#8211; Florence, May 1995, pp. 767-770.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n<\/div><\/div><\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>The assessment of the surface heat flux (HF) distribution is a fundamental element in geothermal prospecting methods, allowing the identification of thermally anomalous areas at relatively modest costs and providing an immediate indication of the geothermal potential of an area.<\/p>","protected":false},"author":1,"featured_media":6440,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_eb_attr":"","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"folder":[36],"class_list":["post-6437","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/pages\/6437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/comments?post=6437"}],"version-history":[{"count":3,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/pages\/6437\/revisions"}],"predecessor-version":[{"id":11871,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/pages\/6437\/revisions\/11871"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/media\/6440"}],"wp:attachment":[{"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/media?parent=6437"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/www.igg.cnr.it\/en\/wp-json\/wp\/v2\/folder?post=6437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}